Guangdong Guangce Instrument Technology Co., Ltd

To be a supplier that provides high-quality products to buyers from all over the world

Manufacturer from China
Verified Supplier
1 Years
Home / Products / Flame Test Chamber /

ODM Plastics UL94 Flame Test Chamber Equipment For Flammability Testing

Contact Now
Guangdong Guangce Instrument Technology Co., Ltd
Visit Website
City:dongguan
Province/State:guangdong
Country/Region:china
Contact Person:MissMia
Contact Now

ODM Plastics UL94 Flame Test Chamber Equipment For Flammability Testing

Ask Latest Price
Video Channel
Place of Origin :China
Brand Name :GC
Certification :ISO
MOQ :1 Set
Packaging Details :Wooden package
Delivery Time :In stock
Payment Terms :TT
Supply Ability :100PCS/Month
Price :Negotiated
Model Number :GC-UL-A
Model NO. :GC-UL-A
Specification :110*650*125(cm)
Trademark :GC
Origin :Guangdong
Customization :Available
Warranty :1 Year
Transport Package :Wooden Box Packaging
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description
UL94 Horizontal Vertical Flame Retardant Test Chamber
Product Description


Model: GC-UL-A

Product Introduction


This testing machine is suitable for detecting and evaluating the combustion characteristics of plastic materials, and performing horizontal and vertical flammability tests on the plastic parts of equipment and appliances. It is equipped with a gas flow meter to adjust the flame size and is driven by a motor. The operation is simple and safe. This instrument can evaluate the flammability of materials or foam plastics such as: V-0, V-1, V-2, HB, 5VA, 5VB, VTM-0, VTM-2.

Test Standards


1. UL94 Fire testing
2. GBT2408-2008 The horizontal and vertical methods for measuring the combustion properties of plastics
3. IEC60695-11-10 Combustion fire test


Specifications

Model GC-UL-A
Control mode Keystroke control
Outer box dimensions 110*650*125(cm)
Box volume ≥0.5m³,With glass observation door
Flame time 0-99 minutes and 99 seconds can be set, accuracy ±0.1 second
Residual flame time 0-99 minutes and 99 seconds can be set, accuracy ±0.1 second
The rest of the burining time 0-99 minutes and 99 seconds can be set, accuracy ±0.1 second
Test gas More than 98% methane/37MJ/m³ natural gas (coal gas is also available)
Burner size parameters Adopt imported lamp, the inner diameter of spray can is 9.5±0.3mm, and the effective length of spray tube is 100±10mm
Flame height It can be adjusted from 20mm to 175mm as required by standard
Flowmeter 105ml/min
Gas leak detection Gas alarm device (optional)
Power AC220V, 50Hz

Inquiry Cart 0