Add to Cart
Hot And Cold Thermal Shock Test Machine For Environmental Test
1.Hot and cold shock test chamber, is a metal, plastic, rubber, electronics and other materials industry necessary test equipment, used to test material structure or composite materials, in an instant under the extreme high temperature and low temperature continuous environment to endure the degree of chemical changes or physical damage caused by thermal expansion and contraction of the sample in the shortest time
2.The system structure of the thermal shock test chamber is divided into high temperature tank (preheating zone) and low temperature tank (precooling zone).
Temperature shock is carried out to achieve the purpose of drastic temperature change, and the test product is static.
3.This test chamber is suitable for assessing the ability of complete machine products, components, parts, materials, etc. to withstand rapid temperature changes.
The temperature shock test is used to evaluate the chemical changes or physical damage of test samples caused by thermal expansion and contraction in the shortest time.
4.It is possible to understand the influence of temperature changes on test samples once or several times in succession.
The main parameters affecting the temperature change test are the high temperature and low temperature values of the temperature change range, the retention time of the test sample at high temperature and low temperature, and the number of cycles of the test and other factors.
5.The hot and cold shock chamber is a necessary test equipment for electronics, LED, metal, plastic, rubber, paint, paint, electronics and other material industries.
Product Name | Shock Test Chamber |
Internal size | 80L:W500*H400*D500mm |
External size | 80L:W1400*H1850*D1500mm |
Temperature shock range | High temperature +60ºC~ +220ºC Low temperature -10ºC~ 80ºC |
Preheating temperature range | 60ºC--200ºC |
High temperature tank heating time | RT~+200ºC≤30min (RT:+10~+30ºC) |
Precooling temperature range | (-10)ºC~ (-70)ºC |
Low temperature tank cooling time | RT~-70ºC≤50min (RT:+10~+30ºC) |
Temperature fluctuation | ±1.0ºC |
Temperature uniformity | ±2.0ºC |
Throttle conversion time | ≤5S |
Impact recovery time | (-60)ºC~(+220)ºC≤5min |
Heating system | Fin-type radiating tube-shaped stainless steel electric heater 1, high temperature tank 9KW 2, low temperature tank 6KW |
Compressor | Original imported French "Taikang" brand fully enclosed compressor |
Evaporator | Multi-stage automatic load capacity adjustment of bullying fins |
Expansion valve | Danvers imported original components from Denmark |